Jump to content

TYK283: Difference between revisions

From PedsAnesthesiaNet
https://pedsanesthesia.net/wikiOLD032021>TYK bot
Bot: Automated import of articles
 
m Text replacement - "<p style="text-align: center;"> About Test Your Knowledge</p>" to "<p style="text-align: center;"> About Test Your Knowledge</p> Category:TYK"
 
(One intermediate revision by the same user not shown)
Line 31: Line 31:
<p style="text-align: center;">[[TYK282|<Prev Question]] --- [[TYK284|Next Question>]]</p>
<p style="text-align: center;">[[TYK282|<Prev Question]] --- [[TYK284|Next Question>]]</p>
<p style="text-align: center;">[[TYK About | About Test Your Knowledge]]</p>
<p style="text-align: center;">[[TYK About | About Test Your Knowledge]]</p>
[[Category:TYK]]

Latest revision as of 02:47, 25 September 2026

Monitoring during orthotopic liver transplantation routinely includes all of the following parameters EXCEPT:

a) Arterial blood gas analysis

b) Coagulation profile

c) Blood glucose level

d) Intracranial pressure

e) Ionized calcium level

Click for Answer

Answer

Answer d. Intracranial pressure monitoring would be very helpful for patients with hepatic failure (with or without OLT); however, there is considerable risk of insertion of a monitor into the cranium of a patient with coagulopathy and thrombocytopenia. At some centers this is performed, but it is not a routine monitor.

Notes

This question originally printed in the Pediatric Anesthesiology Review Topics kindle book series, and appears courtesy of Naerthwyn Press, LLC.

Keywords



<Prev Question --- Next Question>

About Test Your Knowledge