In regards to detection of a venous air embolus, which of the following modalities is most sensitive? | In regards to detection of a venous air embolus, which of the following modalities is most sensitive? | ||
| Line 16: | Line 15: | ||
G. End-tidal carbon dioxide concentration | G. End-tidal carbon dioxide concentration | ||
<div class="mw-customtoggle-TYK_Answer" style="text-align: right; color:#0000ff">Click for Answer</div> | |||
<div class="mw-collapsible mw-collapsed" id="mw-customcollapsible-TYK_Answer"> | |||
<div class="mw-collapsible- | |||
==Answer== | ==Answer== | ||
The answer is B. Doppler is the most sensitive. Echo is the most specific. All others can be used and have signs associated with VAE. | |||
The answer is B. Doppler is the most sensitive. Echo is the most specific. All others can be used and have signs associated with VAE. | |||
==Notes== | ==Notes== | ||
<references /> | <references /> | ||
==Keywords== | ==Keywords== | ||
</div> | </div> | ||
| Line 41: | Line 31: | ||
<p style="text-align: center;">[[TYK11|<Prev Question]] --- [[TYK13|Next Question>]]</p> | <p style="text-align: center;">[[TYK11|<Prev Question]] --- [[TYK13|Next Question>]]</p> | ||
<p style="text-align: center;">[[TYK About | About Test Your Knowledge]]</p> | <p style="text-align: center;">[[TYK About | About Test Your Knowledge]]</p> | ||
[[Category:TYK]] | |||
Latest revision as of 02:28, 25 September 2026
In regards to detection of a venous air embolus, which of the following modalities is most sensitive?
A. Echocardiography
B. Precordial Doppler
C. EKG
D. Right atrial pressure monitor
E. Arterial blood pressure monitor
F. End-tidal nitrogen concentration
G. End-tidal carbon dioxide concentration
Click for Answer
Answer
The answer is B. Doppler is the most sensitive. Echo is the most specific. All others can be used and have signs associated with VAE.