TYK282: Difference between revisions
Appearance
m 1 revision imported |
m Text replacement - "<p style="text-align: center;"> About Test Your Knowledge</p>" to "<p style="text-align: center;"> About Test Your Knowledge</p> Category:TYK" |
||
| Line 31: | Line 31: | ||
<p style="text-align: center;">[[TYK281|<Prev Question]] --- [[TYK283|Next Question>]]</p> | <p style="text-align: center;">[[TYK281|<Prev Question]] --- [[TYK283|Next Question>]]</p> | ||
<p style="text-align: center;">[[TYK About | About Test Your Knowledge]]</p> | <p style="text-align: center;">[[TYK About | About Test Your Knowledge]]</p> | ||
[[Category:TYK]] | |||
Latest revision as of 02:50, 25 September 2026
An appropriate maximum CO2 insufflation pressures for pediatric laparoscopic surgery would be:
a) 5
b) 15
c) 20
d) 25
e) 30
Click for Answer
Answer
Answer b. In general, higher insufflation pressure results in improved surgical field visualization and lower pressure results in improved hemodynamics/venous return. Insufflation pressures greater than 15 may result in significant perturbations of physiology (particularly in infants), but 5 or less is unlikely to provide adequate exposure.
Notes
- This question originally printed in the Pediatric Anesthesiology Review Topics kindle book series, and appears courtesy of Naerthwyn Press, LLC.